For leak detection on house service lines
Features
- Modular instrument concept for gas leak detection. Basic device without pump (diffusion device) or with built-in pump
- Detection of even smallest leaks on service lines and joints
- Large illuminated LCD display
- Self-test when switched-on
- Easy handling by three keys
- User menu
- Function menu for individual instrument configuration (PIN code protected)
- Gas data base with calibration on Methane and other gases, e. g. Propane, Butane, Hexane, Nonane, Hydrogen, Kerosene
- Adjustable test gas concentrations
- Optional minimum sensitivity of 1 ... 100 ppm
- Concentration-dependent signal, audible and visible
- Power supply by accumulators or batteries
Instrinction safety
- EC-type-examination certificate in accordance with ATEX 100a, guideline 94/9/EG
- Certificate No.: TÜV 01 ATEX 1657
- Identification: II 2 G EEx de ib IIB T4
Sensor operation / measuring range
Calibration on methane: Semi-conductor: ppm range, 0 ... 22.000 ppm
Technical data
|
Operating time:
|
|
typ. 8 hours
|
|
Power supply:
|
3 Mignon NiMH accumulators or 3 Mignon Alcaline batteries
|
|
Operating temperature:
|
- 20° ... + 40 °C
|
|
Storage temperature:
|
- 25° ... + 55 °C
|
|
Type of protection:
|
IP 54
|
|
Dimensions (W x H x D):
|
60 x 144 x 35 mm
|
|
Weight:
|
approx. 300 g
|
Accessories
- Leather bag
- Various probe systems
- Test sets / test gases
|