Features
- Modular instrument concept. Basic device without pump (diffusion) or with built-in pump
- Sensor combinations for diverse applications
|
Applications
|
sensors
|
|
warning
|
%LEL
|
|
detecting + warning
|
ppm + %LEL
|
|
warning + measuring
|
%LEL + vol.%
|
|
detecting + measuring
|
ppm + vol.%
|
|
detecting + warning + measuring
|
ppm + %LEL + vol.%
|
- Power supply by rechargeable or disposable batteries
- Micro-processor controlled
- Large illuminated LCD display
- Self-test when switched-on
- Easy handling
- Visual and audible alarms
- Adjustable alarms for each range
- Temperature compensated sensors
- Easy to follow operator menu
- Function menu for instrument configuration (PIN code protected)
- Operator selectable flammable gas menu (option): methane, propane, butane, hexane, nonane, hydrogen, jet fuel
- Adjustable test gas concentrations
Approvals
- Passive protection:
- EC-type-examination certificate in accordance with ATEX 100a, guideline 94/9/EG
- Certificate No.: TÜV 01 ATEX 1657
- Identification: II 2 G EEx de ib IIB T4
- Active protection:
- Function safety test in mode "warning" at "Deutsche Montan Technologie GmbH"
- Test report: PFG-Nr.:413 007 02P
Sensor operation/measuring range
Calibration on methane: ppm-sensor, semi-conductor: 0 ... 22.000 ppm Minimum detection sensitivity 1 ppm %LEL sensor, catalytic combustion: 0 … 4,4 vol.% Minimum detection sensitivity 500 ppm Vol.% sensor, thermal conductivity: 0 … 100 vol.% Minimum detection sensitivity 1 vol.%
Technical data
|
Operating time:
|
|
typically 8 hours
|
|
Power supply:
|
3 Mignon NiMH accumulators or 3 Mignon Alkaline batteries
|
|
Operating temperature:
|
-20 °C ... +40 °C
|
|
Storage temperature:
|
-25 °C ... +55 °C
|
|
Type of protection:
|
IP 54
|
|
Dimensions (W x H x D):
|
60 x 144 x 35 mm
|
|
Weight:
|
approx. 300 g
|
|
|
|
|
Accessories
- Leather bag
- Various probe systems
- Test case/test sets/test gases
|
|